Respuestas cardiorrespiratorias a intensidad umbral: Estudio comparativo entre media sentadilla y cicloergómetro

Biblos-e Archivo/Manakin Repository

Show simple item record

dc.contributor.author Domínguez, R.
dc.contributor.author Garnacho-Castaño, M. V.
dc.contributor.author San Juan, A. F.
dc.contributor.author Pérez-Ruiz, M.
dc.contributor.author García-Fernández, P.
dc.contributor.author Veiga-Herreros, P.
dc.contributor.author Maté-Muñoz, J. L.
dc.date.accessioned 2018-09-18T13:22:37Z
dc.date.available 2018-09-18T13:22:37Z
dc.date.issued 2018-09
dc.identifier.citation Revista Internacional de Medicina y Ciencias de la Actividad Fisica y del Deporte 18.71 (2018): 507-520 es_ES
dc.identifier.issn 1577-0354 es_ES
dc.identifier.uri http://hdl.handle.net/10486/684879
dc.description.abstract Objetivo: Comparar las respuestas respiratorias, de frecuencia cardíaca (FC) y lactato a intensidad de umbral láctico (UL) en media sentadilla (MS) vs cicloergómetro. Métodos: 24 hombres (21,5±1,8 años, 180,1±5,2 cm, 81,9±8,7 kg) con experiencia en el entrenamiento de fuerza realizaron un test incremental progresivo en MS y cicloergómetro para determinar el UL. Durante los test se midieron las concentraciones de lactato, FC, consumo de oxígeno (VO2), producción de dióxido de carbono (VCO2), ventilación pulmonar (VE), equivalente ventilatorio del oxígeno (VE·VO2 -1) y del dióxido de carbono (VE·VCO2 -1). Una t student valoró las diferencias entre las dos modalidades de ejercicio. Resultados: las concentraciones de lactato, FC, VE, VE·VCO2 -1 y VE·VO2 -1 fueron superiores en MS vs cicloergómetro (p<0,05). Conclusiones: el UL puede ser detectado en el ejercicio de MS. Además, la realización de sesiones de entrenamiento contrarresistencias, a intensidad de UL, podrían ser utilizadas para mejorar la resistencia cardiovascular y la fuerza muscular es_ES
dc.description.abstract Objective: To compare respiratory responses, heart rate (HR) and lactate at the intensity of the lactate threshold (LT) between half squat (HS) and cycloergometer. Methods: 24 men (21.5±1.8 years, 180.1 ± 5.2 cm, 81.9±8.7 kg) with experience in resitance performed a progressive incremental test in HS and cycloergometer to determine LT. During such test, the following parameters were measured: blood lactate concentrations, HR, oxygen consumption (VO2), carbon dioxide production (VCO2), pulmonary ventilation (PV), ventilatory equivalent of oxygen (PV·VO2 -1) and ventilatory equivalent of carbon dioxide (PV·VCO2 -1). A t student evaluated the variables analysed among the two exercise modalities. Results: blood lactate concentrations, HR, PV, and PV·VO2 -1 and PV·VCO2 -1 were higher in HS than in cycloergometer (p <0.05). Conclusions: LT can be detected in HS exercise. Furthermore, the resistance training sessions to the intensity of LT might be used in training sessions which seek to improve cardiovascular endurance and muscle strength en_US
dc.format.extent 14 pag. es_ES
dc.format.mimetype application/pdf en
dc.language.iso spa en
dc.publisher Universidad Autónoma de Madrid. Comunidad Virtual Ciencias del Deporte es_ES
dc.relation.ispartof Revista Internacional de Medicina y Ciencias de la Actividad Fisica y del Deporte es_ES
dc.rights © 2018, Universidad Autónoma de Madrid y CV Ciencias del Deporte es_ES
dc.subject.other Resistencia es_ES
dc.subject.other Fuerza es_ES
dc.subject.other Entrenamiento contrarresistencias es_ES
dc.subject.other Umbral anaeróbico es_ES
dc.subject.other Transición aeróbica-anaeróbica es_ES
dc.title Respuestas cardiorrespiratorias a intensidad umbral: Estudio comparativo entre media sentadilla y cicloergómetro es_ES
dc.title.alternative Cardiorrespiratory responses at threshold intensity: Comparative between half squat vs cycle ergometer en_US
dc.type article en
dc.subject.eciencia Deportes es_ES
dc.subject.eciencia Medicina es_ES
dc.relation.publisherversion http://dx.doi.org/10.15366/rimcafd2018.71.007 es_ES
dc.identifier.doi 10.15366/rimcafd2018.71.007 es_ES
dc.identifier.publicationfirstpage 507 es_ES
dc.identifier.publicationissue 71 es_ES
dc.identifier.publicationlastpage 520 es_ES
dc.identifier.publicationvolume 18 es_ES
dc.type.version info:eu-repo/semantics/publishedVersion en
dc.rights.accessRights openAccess en


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record