Mañana, JUEVES, 24 DE ABRIL, el sistema se apagará debido a tareas habituales de mantenimiento a partir de las 9 de la mañana. Lamentamos las molestias.

Show simple item record

dc.contributor.authorGil, Andrea
dc.contributor.authorHernández, Carlos S.
dc.contributor.authorPérez-Merino, Pablo
dc.contributor.authorRubio, Marcos
dc.contributor.authorVelarde, Gonzalo
dc.contributor.authorAbellanas-Lodares, María
dc.contributor.authorRomán-Daza, Ángeles
dc.contributor.authorAlejandre, Nicolás
dc.contributor.authorJiménez-Alfaro, Ignacio
dc.contributor.authorCasares, Ignacio
dc.contributor.authorShivang R., Dave
dc.contributor.authorLim, Daryl
dc.contributor.authorLage Negro, Eduardo 
dc.contributor.otherUAM. Departamento de Cirugíaes_ES
dc.contributor.otherUAM. Departamento de Tecnología Electrónica y de las Comunicacioneses_ES
dc.contributor.otherInstituto de Investigación Sanitaria Fundación Jiménez Díaz (IIS-FJD)es_ES
dc.date.accessioned2021-07-29T08:03:28Z
dc.date.available2021-07-29T08:03:28Z
dc.date.issued2020-10-28
dc.identifier.citationPlos One 15.10 (2020): e0240933es_ES
dc.identifier.issn1932-6203es_ES
dc.identifier.urihttp://hdl.handle.net/10486/696862
dc.description.abstractPurpose To assess the performance of an open-view binocular handheld aberrometer (QuickSee) for diagnosing refractive errors in children. Methods 123 school-age children (9.9 ± 3.3 years) with moderate refractive error underwent autorefraction (AR) with a standard desktop device and subjective refraction (SR), with or without cycloplegia to determine their eyeglass prescription. Measurements with QuickSee (QS) were taken in 62 of these patients without cycloplegia (NC), and in 61 under cycloplegia (C). Differences in refraction values (AR vs SR vs QS) as well as the visual acuity (VA) achieved by the patients with each method (QS vs SR) were used to evaluate the performance of the device in measuring refractive error. Results The spherical equivalent refraction obtained by QS agreed within 0.5 D of the SR in 71% (NC) and 70% (C) of the cases. Agreement between the desktop autorefractor and SR for the same threshold was of 61% (NC) and 77% (C). VA resulting from QS refractions was equal to or better than that achieved by SR procedure in 77% (NC) and 74% (C) of the patients. Average improvement in VA with the QS refractions was of 8.6 and 13.4 optotypes for the NC and C groups respectively, while the SR procedure provided average improvements of 8.9 (NC) and 14.8 (C) optotypes. Conclusions The high level of agreement between QuickSee and subjective refraction together with the VA improvement achieved in both study groups using QuickSee refractions suggest that the device is a useful autorefraction tool for school-age children.en_US
dc.description.sponsorshipEduardo Lage is funded by the Ramon y Cajal program from the Spanish Ministry of Economy, Industry and Competitivity (RYC-2016- 21125). Pablo Perez-Merino was funded by the Juan de la Cierva program from the same Ministry (FJCI-2015-27101). Carlos S. Hernandez and Andrea Gil are funded by the Madrid Regional Government through IND2019/TIC-17116 grant PlenOptika Inc. provided support in the form of salaries for authors AG, MR, CSH, IC, SD, and DL, but did not have any additional role in the study design, data collection and decision to publish.en_US
dc.format.extent11 pag.es_ES
dc.format.mimetypeapplication/pdfen
dc.language.isoengen_US
dc.publisherPublic Library of Scienceen_US
dc.relation.ispartofPlos Oneen_US
dc.rights© 2020 Gil et ales_ES
dc.subject.otherQuickSeeen_US
dc.subject.otherdiagnosing refractive errorsen_US
dc.subject.otherchildrenen_US
dc.subject.otherautorefraction toolen_US
dc.titleAssesment of the QuickSee wavefront autorefractor for characterizing refractive errors in school-age childrenen_US
dc.typearticleen
dc.subject.ecienciaInformáticaes_ES
dc.subject.ecienciaMedicinaes_ES
dc.relation.publisherversionhttps://doi.org/10.1371/journal.pone.0240933es_ES
dc.identifier.doi10.1371/journal.pone.0240933es_ES
dc.identifier.publicationfirstpagee0240933-1es_ES
dc.identifier.publicationissue10es_ES
dc.identifier.publicationlastpagee0240933-11es_ES
dc.identifier.publicationvolume15es_ES
dc.relation.projectIDGobierno de España. RYC-2016- 21125es_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersionen
dc.rights.ccReconocimientoes_ES
dc.rights.accessRightsopenAccessen
dc.authorUAMJiménez Alfaro, Ignacio (269064)
dc.authorUAMLage Negro, Eduardo (271794)
dc.facultadUAMEscuela Politécnica Superior
dc.institutoUAMInstituto de Investigación Sanitaria Fundación Jiménez Díaz (ISS-FJD)


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record